HMV-G21 Series/HMV-G21 FA Type/HMV-G20 Series

Micro Vickers Hardness Tester

Standardized automatic length measurement function using a CCD camera built in a novel G frame (G21 Series)
Capable of automatically recognizing the total image of the sample and the sample edges (FA Type)

HMV-G21 Series

  • Equipped with an automatic reading function, adopting highly specialized algorithms.
    Even scratched samples can be measured with good repeatability.
  • User-friendly software has been adopted that allows all the information to be seen at a glance. This improves operational efficiency and eliminates errors.
  • Equipped with a smart, compact built-in CCD camera mechanism. The instrument can be installed neatly and simply, with no need for wiring arrangements.
  • Thanks to the routine inspection graph generating function, the data can be assessed in chronological order. The stability of the testing system can be evaluated using statistical methods, which means the instrument can be used effectively for obtaining ISO 17025*2) and ISO 16949*2) certification.
ITEM SPECIFICATIONS
Model HMV-G21S HMV-G21ST HMV-G21D HMV-G21DT
Maximum Number of
Indenters Attached
1 2
Standard Indenters
Provided
Vicker ndenter
Maximum Number of 
Objective Lenses
Attached
2 4
Standard Objective
Lenses Provided
40× 40× 10×
Test Force Nine force types: 98.07 mN, 245.2 mN, 490.3 mN, 980.7 mN, 1.961 N, 2.942 N, 4.903 N, 9.807 N,
(When low test force option is applied) Three types in addition to the above:
and 19.61 N (HV0.01, 0.025, 0.05, 0.1, 0.2, 0.3, 0.5, 1, and 2), and 4 arbitrary settings
9.807 mN, 19.61 mN, and 49.04 mN (HV0.001, HV0.002, and HV0.005)
Loading unit Automatic loading and automatic force changing
XY Stage Manual type Area: 100 mm × 100 mm; stroke: ±12.5 mm; sample: max. height of 100 mm
Instrument lateral direction (width direction): unlimited; instrument depth direction: for sample
width of 120 mm or less, unlimited*5; for sample width of 120 mm or more: 200 mm max.
Z axis stroke: 60 mm; spacers provided: 40 mm thick
External Dimensions Approx. W 350 mm × D 570 mm × H 540 mm
Weight Approx. 44 kg
Power Requirements Main body : Single phase AC 100-115 V, 1 A AC230 V, 0.5 A
Provide a grounding wire. (Grounding resistance 100 Ω max.)

* Shimadzu reserves right to change product design without notice.

HMV-G21 FA Type

  • A stage view function has been adopted that allows the user to observe the total image of the sample for specifying arbitrary positions. It is easy to test a desired test position. Furthermore, the system is equipped with a sample shape recognition function that detects the edges of the sample. Test positions can be configured easily along the sample edges.
  • An Excel compatible programming function has been adopted. Test patterns can be programmed even with an office PC.
ITEM SPECIFICATIONS
Model HMV-G-FA-S HMV-G-FA-D
Maximum Number of
Indenters Attached
1 2
Standard Indenters
Provided
Vicker ndenter
Maximum Number of 
Objective Lenses
Attached
2 4
Standard Objective
Lenses Provided
40× extra-long working distance type 5×
Test Force Nine force types: 98.07 mN, 245.2 mN, 490.3 mN, 980.7 mN, 1.961 N, 2.942 N, 4.903 N, 9.807 N,
(When low test force option is applied) Three types in addition to the above:
and 19.61 N (HV0.01, 0.025, 0.05, 0.1, 0.2, 0.3, 0.5, 1, and 2), and 4 arbitrary settings
9.807 mN, 19.61 mN, and 49.04 mN (HV0.001, HV0.002, and HV0.005)
Loading unit Automatic loading and automatic force changing
XY Stage Electric type Area: 125 mm × 125 mm; 
stroke: ±25 mm; sample: max. height of 65 mm
Instrument lateral direction (width direction): unlimited
Instrument depth direction: for sample width of 120 mm or less,
unlimited for sample width of 120 mm or more, 200 mm max.
Z axis stroke: 45 mm; spacers provided: 30 mm thick
External Dimensions Approx. W 350 mm × D 570 mm × H 540 mm
Weight Approx. 48 kg
Power Requirements Single phase AC 100-115 V, 1 A AC230 V, 0.5 A
Provide a grounding wire. (Grounding resistance 100 Ω max.)

* Shimadzu reserves right to change product design without notice.

HMV-G20 Series

  • The design now incorporates an open space at the center of the frame. This makes it possible to place long samples at test positions that could not be tested conventionally.
  • A USB direct transmission function has been adopted, so data can be stored automatically on a USB memory stick. Test data can be extracted and transferred without using a PC. Furthermore, a color LCD touch panel has been adopted with a big, user-friendly display. This improves the visual ease of use, enabling fast, efficient measurements.
ITEM SPECIFICATIONS
Model HMV-G20S HMV-G20ST HMV-G20D HMV-G20DT
Maximum Number of
Indenters Attached
1 2
Standard Indenters
Provided
Vicker ndenter
Maximum Number of 
Objective Lenses
Attached
2 4
Standard Objective
Lenses Provided
40× 40×, 10×
Test Force Nine force types: 98.07 mN, 245.2 mN, 490.3 mN, 980.7 mN, 1.961 N, 2.942 N, 4.903 N, 9.807 N,
(When low test force option is applied) Three types in addition to the above:
and 19.61 N (HV0.01, 0.025, 0.05, 0.1, 0.2, 0.3, 0.5, 1, and 2), and 4 arbitrary settings
9.807 mN, 19.61 mN, and 49.04 mN (HV0.001, HV0.002, and HV0.005)
Loading unit Automatic loading and automatic force changing
XY Stage Manual type Area: 100 mm × 100 mm; 
stroke: ±12.5 mm; sample: max. height of 100 mm
Instrument lateral direction (width direction): 
unlimited instrument depth direction: 
for sample width of 120 mm or less, unlimited; 
for sample width of 120 mm or more: 140 mm max.
Z axis stroke: 60 mm; spacers provided: 40 mm thick
External Dimensions -
Weight Approx. 44 kg
Power Requirements Main body: Single phase AC 100-115 V, 1 A AC230 V, 0.5 A
Provide a grounding wire. (Grounding resistance 100 Ω max.)

* Shimadzu reserves right to change product design without notice.

For Research Use Only. Not for use in diagnostic procedures. Please contact us to check the availability of these products in your country.