NOA-7100 - Specs
Transportable NOx-O2 Gas Analyzer
Standard type
Two standard types are available
Type 1
| Measurement components |
NOx, O2 |
|---|---|
| Measurement range |
NOx: 0 - 25/ 50/ 100/ 250/ 500/ 1000/ 2500/4000 ppm |
| Measurement principle |
NOx: Atmospheric pressure chemiluminescence method; O2: Limiting current zirconia type method |
| Repeatability |
Within ±0.5% of full scale |
| Zero Drift |
Within ±1% of full scale per day (25 ppm range: within ±1.5% of full scale per day) |
| Span Drift |
Within ±1.5% of full scale per day |
| Linearity |
Within ±2% of full scale |
| Response time (*2) |
NOx: Approx. 20/30/60 sec (Switching is configurable.) |
| Gas sample amount |
Approx. 2 L/min |
| Display |
Liquid crystal display, able to display 3 items at a time |
| Transmission Output |
0-1VDC, 3 channels, insulated output (individual channels not insulated) |
| Wireless data transmission |
Equipped |
| Data output to external media (*3) |
Measurement data stored in the internal memory of the analyzer can be written to USB flash drives in CSV file format; can also be output to a computer via Wi-Fi or LAN cable connection. |
| Permissible ambient temperature (*4) |
5-40℃; must not be exposed to direct sunlight or radiant heat |
| Permissible ambient humidity (*4). |
Relative humidity 90%RH or less |
| Power Requirements |
Choose from 110, 115, 120, 127, 220, 230, 240 VAC 50-60 Hz, |
| Dimensions |
W260 x H452 x D420 mm (does not include protrusions) |
| Weight (analyzer) |
Approx. 16 kg |
| External drain separator |
Fitted |
| Sample gas conditions (*5) |
[ At NOA-7100 inlet port ] Pressure: -980 to + 980 Pa; |
| External Signal Input |
0-1VDC, 1 channel, Signal input from an external analyzer, display (Data can be saved) |
Type 2
| Measurement components |
NOx, NO, NO2 (*1) |
|---|---|
| Measurement range |
NOx, NO, NO2: 0 - 100/ 250/ 500/ 1000/ 2500/ 4000 ppm |
| Measurement principle |
NOx: Atmospheric pressure chemiluminescence method; O2: Limiting current zirconia type method |
| Repeatability |
Within ±0.5% of full scale |
| Zero Drift |
Within ±1% of full scale per day (25 ppm range: within ±1.5% of full scale per day) |
| Span Drift |
Within ±1.5% of full scale per day |
| Linearity |
Within ±2% of full scale |
| Response time (*2) |
NOx/NO: Within 90 sec |
| Gas sample amount |
100 mL/min |
| Display |
Liquid crystal display, able to display 3 items at a time |
| Transmission Output |
0-1VDC, 3 channels, insulated output (individual channels not insulated) |
| Wireless data transmission |
Equipped |
| Data output to external media (*3) |
Measurement data stored in the internal memory of the analyzer can be written to USB flash drives in CSV file format; can also be output to a computer via Wi-Fi or LAN cable connection. |
| Permissible ambient temperature (*4) |
5-40℃; must not be exposed to direct sunlight or radiant heat |
| Permissible ambient humidity (*4). |
Relative humidity 90%RH or less |
| Power Requirements |
Choose from 110, 115, 120, 127, 220, 230, 240 VAC 50-60 Hz, |
| Dimensions |
W260 x H452 x D420 mm (does not include protrusions) |
| Weight (analyzer) |
Approx. 16 kg |
| External drain separator |
Not fitted |
| Sample gas conditions (*5) |
[ At NOA-7100 inlet port ] Pressure: -980 to + 980 Pa; |
| External Signal Input |
0-1VDC, 1 channel, Signal input from an external analyzer, display (Data can be saved) |
Small flow rate set : Not fitted
| Response time (*2) |
NOx: Approx. 20/30/60 sec (Switching is configurable.) |
|---|---|
| Gas sample amount |
Approx. 2 L/min |
| Repeatability |
Within ±0.5% of full scale |
| Span Drift |
Within ±1.5% of full scale |
| Measurement components |
NOx or NOx/O2 |
| Measurement range |
NOx: 0 - 25/ 50/ 100/ 250/ 500/ 1000/ 2500/ 4000 ppm |
Small flow rate set : Fitted
| Response time (*2) |
NOx/NO: Within 90 sec |
|---|---|
| Gas sample amount |
100 mL/min |
| Repeatability |
Within ±0.5% of full scale |
| Span Drift |
Within ±1.5% of full scale |
| Measurement components |
NOx |
| Measurement range |
NOx: 0-100/ 250/ 500/ 1000/ 2500/ 4000 ppm |
| Measurement principle |
NOx: Atmospheric pressure chemiluminescence method |
|---|---|
| Repeatability |
Within ±0.5% of full scale |
| Zero Drift |
Within ±1% of full scale per day (25 ppm range: within ±1.5% of full scale per day) |
| Span Drift |
Within ±1.5% of full scale |
| Linearity |
Within ±2% of full scale |
Special specifications
In addition to the standard model, it is possible to specify constituents, and if the small flow rate set, communication set, or NOx-NO switching solenoid valve set is provided.
| Measurement components |
1 constituent (NOx) or 2 constituents (NOx, O2) (*5) |
|---|---|
| Measurement range |
NOx: 0-25/50/100/250/500/1000/2500/4000 ppm |