inspeXio™ 7000 - Specs

Microfocus X-Ray CT System

Add Bookmark

Model inspeXio 7000
X-Ray Generator Rated Power 135 W
Max. Tube Voltage 225 kV
Max. Tube Current 1000 μA
X-Ray Detector Flat panel detector
X-Ray Detector Size 16 inch
X-Ray Detector Shades Of Gray 16-bit = 65,536 shades of gray
Max. Input Resolution (For Offset Scan) Approx. 14,000,000 pixels
Max. Sample Size And Weight,
And Max. CT-Scan Region
Max. Sample Size And Weight, And Max. CT-Scan Region
Max. CT Image Size Two-Dimensional CT 4096 × 4096
Cone-Beam CT 4096 × 4096
High-Performance Computing System Version HPCinspeXio ver.3.0
For 1024 × 1024 pixel CT images 10 sec or less after completing data acquisition
Scan Support
Functions
Positioning via an Exterior Camera 135 W
3D CT Scan Region Display Function 225 kV
Recommend Scanning 1000 μA
CT Stage Max. Stroke SOD Axis *1 890 mm
SID Axis *2 Switchable between 3 levels (600, 800, 1200)
CT-Z Axis 300 mm
Scan Modes Normal scan, half scan, offset scan, FS scan*3 , 2DCT*4 , CBCT*5 
CT Data Acquisition Time Any value from 10 sec to 60 min
Shield Box Size And Mass W2170 × D1350 × H1858 mm, approx. 3100 kg
Power
Requirements
Main Unit AC 200/220/230/240 V (tap switching) ±10 %, 50/60 Hz, 2 kVA
Control Computer *6 *7 AC100 V – AC 240 V ±10 %, 50/60 Hz, 1.5 kVA
Ground Type-D ground (100 ohm max. ground resistance)
CE, KC Yes
External Leakage Dose 0.5 μSv/h or less
Option Operation Box. Exterior Camera Retraction Unit
  • *1 SOD axis: The SOD (= Source to Object Distance) axis is used to change the distance between the focal point and sample.
  • *2 SID axis: The SID (= Source to Image Distance) axis is used to change the distance between the focal point and detector.
  • *3 FS scan: The fan-shaped (FS) scan obtains CT images by scanning the sample at 60, 90, and 120 degree rotation angles.
  • *4 2DCT: Two-dimensional computed tomography (2DCT) obtains one or three CT images from each CT scan.
  • *5 CBCT: Cone beam computed tomography (CBCT) obtains several hundred CT images from each CT scan.
  • *6 For Japanese specifications, table tap and PC inlet cables (3 pcs) are included.
  • *7 Except for Japanese specifications, table tap and PC inlet cables (3 pcs) are not included. Please prepare products in compliance with each country's standards.
{"title":"Specification Sheet Downloads","description":"Download the latest specification sheets.","source":"product","key":5806,"max":30,"filter_types":["spec_sheet"],"link_title":"View other Downloads","link_url":""} {"title":"Downloads","description":"Download the latest brochure.","source":"product","key":5806,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]}